Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

A specific implementation of  Well Testing based on recording and interpretation of borehole (downhole or THP) pressure response to the pre-designed sequence of increasing and decreasing flow rate variations (also called "cycles" or "pulses" ) at one or more disturbing wells wells (called "generators" or "pulsers") inducing pressure pulse propagation across the field.

The usual practise is to create 3 5 5 10 pulses.

The pressure response can be recorded in
to rate variation is recorded in the same well where the flowrate is varying (and in this case is called Self-Pulse Test

...

or in the

...

 offset wells (and in this case is called Pressure Pulse Interference Test)



Workflow

...


1

Designing flowrate variation pulse sequence for disturbing wells (also called generators)  based on the field primary data 

2

Field operations on suspending the downhole gauges (if PDG is not available)

3

Performing flowrate variations according to the PCT design

4

Retrieving the downhole gauges

5

Downloading the data from the downhole and surface gauges

6

Primary data processing (gauge syncronization and filtering)

7

Implementing pressure pulse-code decomposition (PCD)

8

Recognising the PTA type-library diffusion models for decomposed DTR/CTR and type-curve fitting them with analytical and/or numerical pressure diffusion models 

...