Relates pressure drop  p_{out} - p_{in}  on the choke with the flowrate through the choke q arising from fluid friction with choke walls:

(1) p_{out} - p_{in} = \frac{\rho}{8.05 \, d^4_D \, C_D^2} \cdot q^2

where

\rho

fluid  density

d_D

choke diameter

C_D

choke coefficient (see (2))

(2) C_D = \frac{d_D}{d} + 0.3167 \cdot \left( \frac{d}{d_D} \right)^{0.6} + 0.025 \cdot \big [ \log {\rm Re} - 4 \big ]

where

d

internal diameter of the incharge/discharge pipe

{\rm Re}

Reynolds number


See also


Physics / Fluid Dynamics / Pipe Flow Dynamics / Pipe Flow Simulation (PFS)

Pipeline Engineering / Pipeline / Choke