See Also
...
Petroleum Industry / Upstream / Production / Subsurface Production / Field Study & Modelling / Production Analysis / Waterflood Diagnostics
Ratio of oil production rate
to water injection rate : LaTeX Math Block |
---|
|
{\rm PIR} = \frac{q_O}{q_{WI}} |
It measures how efficiently waterflood supports the oil production.
The PIR can be expressed through the current VRR as:
LaTeX Math Block |
---|
|
{\rm PIR}= \frac{1}{\rm VRR} \cdot \frac{1-Y_w}{Y_w + (1-Y_w) \, \left[ \frac{B_o}{B_w} + \frac{B_g}{B_w} \, ( {\rm GOR} - R_s) \right] } |
...
LaTeX Math Block Reference |
---|
anchor | VRR_PIR |
---|
page | Voidage Replacement Ratio (VRR or Instantenous VRR) |
---|
|
...