The drainage volume difference
LaTeX Math Inline |
---|
body | \delta V_{\phi} = V_{\phi, 2} - V_{\phi, 1} >0 |
---|
|
may be related to the fact that water injection
W2 is shared between
and another reservoir or with another producer.
Case #1 – Constant flowrate
...
production:
The pressure response
in producer
W1 to the flowrate variation
in injector
W2:
...
Expand |
---|
|
Consider a pressure convolution equation for the BHP in producer W1 with constant flowrate production at producer W1 and varying injection rate at injector W2 : LaTeX Math Block |
---|
anchor | Case2_PSS_p11 |
---|
alignment | left |
---|
| p_1(t) = p_i - \int_0^t p_{u,\rm 11}(t-\tau) dq_1(\tau) - \int_0^t p_{u,\rm 21}(t-\tau) dq_2(\tau) = p_i - \int_0^t p_{u,\rm 21}(t-\tau) dq_2(\tau) |
Consider a step-change in injector's W2 flowrate at zero time , which can be written as: LaTeX Math Inline |
---|
body | dq_2(\tau) = \delta q_2 \cdot \delta(\tau) \, d\tau |
---|
| .The responding pressure variation in producer W1 will be: LaTeX Math Block |
---|
anchor | Case2_PSS_p11 |
---|
alignment | left |
---|
| \delta p_1(t) = p_1(t)-p_i = - \int_0^t p_{u,\rm 21}(t-\tau) \delta q_2 \cdot \delta(\tau) \, d\tau = - p_{u,\rm 21}(t) \cdot \delta q_2 |
|
Case #2 – Constant BHP:
The flowrate response
in producer
W1 to the flowrate variation
in injector
W2:
...