DeploymentBorehole
Log NameCFS
Math Symbol

f_{CFS}

Measured PropertyFluid flow velocity along the tool
Sensor TypeMechanical Spinner
Units
SIHz 
Oil MetricRPM  = 60 Hz
Oil Field

RPM  = 60 Hz


Applications



  • Assesing donwhole flowrate


Sample Logs




Tool Schematic





Mathematical Model



f_{CFS} = S_{\rm slope} \cdot ( v - v_{th})

where  S_{\rm slope} is some constant depending on tool construction and well completion ,  v_{th} a critical value of the flow speed which can initiate spinner rotation,  v – flow velocity.