Volumetric flowrate of water measured at separatorSPE Standard Conditions (STP).
Usually produced from water phase only.
For volatile oil fluid model the For MBO fluid @model the water surface flowrate
LaTeX Math Inline | ||
---|---|---|
|
LaTeX Math Inline | ||
---|---|---|
|
LaTeX Math Block | ||||
---|---|---|---|---|
| ||||
q_WW^{\uparrow} = \frac{q_w}{B_w} |
where
| formation volume factors between separator and sandface pressure/temperature conditions |
It relates to Liquid production rate at surface as:
LaTeX Math Block | ||||
---|---|---|---|---|
| ||||
q_W^{\uparrow} = Y_W \, q_L^{\uparrow} |
See Also
...
Petroleum Industry / Upstream / Subsurface E&P Disciplines / Well Testing (WT) / Flowrate Testing / Flowrate
...