Specific type of Leak Detection based on Temperature logging.

It normally consists of two logging passes:

  • shut-in conditions
  • bleeding conditions


The fluid leakage reveals itself through the difference in noise patterns of two logging passes (see Fig. 1).


Fig. 1. Sample picture of fluid leakage captured by Temperature logging



See Also


Petroleum Industry / Upstream /  Data Acquisition / Well & Reservoir Surveillance / Leak Detection

Production Logging @ Leak Detection ][ Noise Logging @ Leak Detection ]

Temperature logging ]