  • M = {  VO , ED , yx, x, y,   x, JW0 , k*ro(s), k*rw(s) }  – totally 8 constants  and two arrays 

...

  • all constants are positive

  • 0 < k*ro(s) < 1, 0 < k*rw(s) < 1

  • default values k*ro(s), k*rw(s) – reduced  RPM set by the tables or RPM Corey @model

typical number of s-points = 5

Model fitting

...


Source data corrections:

...

P = Pi +   ( yW  Bw ‧ ΣQW + Bo ‧ ΣQO↑ + xW ‧  Bw ‧ ΣQW + xG ‧  Bg ‧ ΣQG  )‧ Pi ‧ xP /VO 

sw = soi wi + (sor - swi) ‧ ED ‧  ΣQO / VO

JO = krok*ro(sw) ‧ xJ

JW = JW0 + krwk*rw(sw) ‧ xJ

JG = R‧ JOkro(d), krw(d) are set by tables or RPM Corey @model.


See Also

...

Petroleum Industry / Upstream /  Production / Subsurface Production / Field Study & Modelling / Production Analysis / Capacitance Resistance Model (CRM) / Capacitance-Resistivity Model (CRM) @model

...